Our NOC and Co-Location Datacenter

Datacenter:
Our servers are located at the prestigious and state of the art DimeNOC Datacenter located outside of Orlando Florida, USA. Our Support Staff and Network Technicians are on staff 24/7/365 for all of your technical needs. Take a brief tour below to learn more about all of the security, power and network infrastructure at work to keep your business online 24/7.

  • 20,000 square feet
  • Single-story building with concrete masonry perimeter walls
  • Category 4 storm resistant
  • Client Conference Room
  • Client Lounge Area
  •  

    Security:
    Data centers are staffed 24/7, both entrances and exits are electronically secured and continuously monitored via closed-circuit cameras. DimeNOC is only accessible to qualified network, datacenter technicians and authorized co-location clients.

  • On-site personnel 24x7x365
  • Electronic access control and physical security
  • Man-trap entry & badge-only access provided by ADT Security
  • Video surveillance throughout
  • Biometric Hand Readers


  • Power Systems:
    Power systems in DimeNOC's datacenter are proven to run uninterrupted even during long blackouts and brownouts. All networking equipment and servers are connected to Uninterruptible Power Supply (UPS) systems. On-site diesel generators are tested regularly and can run indefinitely if utility power feeds fail.

  • 1 X 500KW Caterpillar Diesel Generator
  • 1 X 1250KW Katolight Diesel Generator
  • 1 X 500KVA Powerware 9315 UPS
  • 2 X 480KVA Powerware UPS
  • 5 X Battery Strings (providing 15 minutes of runtime at full load)
  • 2,700 Gallons of fuel capacity for generators
  • Routine systems testing and maintenance
  •  

    Network Connectivity and Bandwidth:
    We deploy Cisco routers, switching at the distribution layer to improve network resilience, service levels and increase agility. We provide the highest standards of connectivity and packet delivery. Our center provides redundant GiGE fiber connections to multiple tier 1 backbone providers.

  • 10GE - Level3 Communications
  • 10GE - Diverse Dark Fiber to Miami Nap of Americas
  • 10GE - Backhaul to Miami Nap of Americas
  • 1GE - Public Peering (NOTA)
  • 1GE - Global Crossing
  • 1GE - Savvis
  • Private Network Availability
  •  

    Network Tests:

    72.29.70.131 - 128MB Test
    72.29.70.131 - 1GB Test


    Climate Control & Air Conditioning Systems:
    Fully redundant cooling systems insure that the datacenter is always operating at a temperature of optimum server performance.

  • Constant 72F/45% humidity precision control
  • Separate cooling zones
  • 6 X 30 Ton Liebert CRAC units
  • 1 X 25 Ton Package Air unit
  • 1 X 15 Ton Package Air unit
  • 1 X 12 Ton Package Air unit
  • 1 X 5 Ton Liebert CRAC unit